pumps and pumping systems  
 
 

SKA self-priming pumps


Applications

SKA self-priming rotodynamic, pumps with side ring channel and open impeller, serve to pump liquids within the corrosion resistance limits of materials used for their construction. Liquids of a temperature up to 110oC, discharged liquid density up to 1 300 kg/m3 and viscosity up to 150 mm2/s contaminated with solid particles up to 0.5 mm in trace amounts can be pumped. Pumps can cooperate with 50 Hz or 60 Hz motors.

SKA pumps can be used in:

  • waterwork systems, ,
  • individual farms,
  • industry.

Technical specifications

capacity 0,3 ÷ 30 m3/h
delivery head up to 310 m *
pumped liquid temperature up to 110 oC
liquid density up to 1300 kg/m3
liquid viscosity up to 150 mm2/s
mass 34,0 ÷ 409,0 kg
motor power 0,55 ÷ 30,0 kW
rotation speed 1450 obr/min (50 Hz) and 1800 obr/min (60 Hz)
rotations direction clockwise, looking on the pumps from drive side
shaft seal cord seal or end-face seal
*

Delivry head is lowered by 10% for hot liquids from + 70oC to +110oC.

  • manometric pressure allowed for SKA.2 pumps cannot exceed 2.5 MPa,
  • for the remaining 1 to 4 stage pumps, manometric pressure cannot exceed 2.0 MPa and for 5 to 8 stage pumps - 3.2 MPa,
  • for 1 to 4 stage pumps with an oval flange the allowed pressure cannot exceed 0.8 MPa.

Technical data with division into individual types

Pump variety Type/size Type dimension Parameters
Capacity
Q [m3/h]
Delivery head
H [m]
SKA 2 05, 06 0,3 ÷ 2,1 15,0 ÷ 96,0
3 01, 02, 03, 04, 05, 06, 07, 08 1,0 ÷ 3,0 11,0 ÷ 224,0
4 01, 02, 03, 04, 05, 06, 07, 08 1,8 ÷ 4,5 8,0 ÷ 204,0
5 01, 02, 03, 04, 05, 06, 07, 08 3,5 ÷ 7,5 11,0 ÷ 310,0
6 01, 02, 03, 04, 05, 06, 07, 08 6,0 ÷ 12,0 16,0 ÷ 222,0
7 01, 02, 03, 04, 05, 06, 07, 08 10,5 ÷ 20,0 10,0 ÷ 291,0
8 01, 02, 03, 04, 05, 06 16,0 ÷ 30,0 15,0 ÷ 187,0

Product marking structure

S K
 
A
 
2
 
0 5
 
2
 
1 0 2 0
 
3
 
1 0 3
 
1
a a
 
f
 
b
 
c c
 
d
 
e1 e2 e3 e4
 
h
 
i i i
 
k


a a - classification group
f - product variety (A - with ball bearing at suction and at discharge side)
b - pump type/size (2 ÷ 8)
c c - pump type/dimension (number of stages) (01 ÷ 08)
d - pump material execution as in MATERIAL EXECUTION
e1 e2 e3 e4 - pump constructional execution as in CONSTRUCTIONAL EXECUTION
h - supply completeness as in SUPPLY COMPLETENESS
i i i - motor type
k - product cosmetics as in PRODUCT COSMETICS (protective coatings)

Material execution of SKA pumps

SKA pumps are produced in six material executions

Pump elements Material "d"
1 2 3 4 5 6
Casing gray cast iron tin bronze gray cast iron gray cast iron cast carbon steel austenitic cast steel
Members gray cast iron chromium cast iron gray cast iron chromium cast iron cast carbon steel austenitic cast steel
Impeller tin bronze tin bronze ductile cast iron tin bronze tin bronze special austenitic cast steel
Shaft stainless steel acid-proof steel stainless steel acid-proof steel stainless steel acid-proof steel
Shaft seal soft-cord seal *
mechanical *

* material selection of seals depends on pumped liquid

Constructional execution

Constructional
execution No
e1 e2 e3 e4
Constructional execution SKA pump
2 3 4 5 6 7 8
1010 Pump with cord seal
for -30oC ÷ +70oC liquid temperature
 
1020 Pump with cord seal
for -30oC ÷ +70oC liquid temperature
           
1040 Pump with cord seal and chamber
for -30oC ÷ +70oC liquid temperature
1050 Pump with cord seal and circulation pipe
for -30oC ÷ +70oC liquid temperature
1060 Hydrophore pump with cord seal
for 0oC ÷ +40oC liquid temperature (concerns 01 ÷ 02 stages)
         
1100 Pump with A1-type single front seal
for -30oC ÷ +70oC liquid temperature
   
1110 Pump with V-type single front seal
for -30oC ÷ +70oC liquid temperature
 
1120 Pump with single front seal of V-type at suction side, of VB-type at discharge side,
for -30oC ÷ +70oC liquid temperature
 
1130 Pump with single front seal of US-type,
for -30oC ÷ +70oC liquid temperature
 
1170 Pump with single front seal of 2100-type,
for -30oC ÷ +70oC liquid temperature
           
1230 Pump with single front seal of 58U-type
for -30oC ÷ +70oC liquid temperature
     
1350 Pump with single front seal of A1-type, with quenching, for -30oC ÷ +70oC liquid temperature    
1360 Pump with single front seal of V-type, with quenching, for -30oC ÷ +70oC liquid temperature  
1370 Pump with single front seal of V-type at suction side, VB-type at discharge side, with quenching, for -30oC ÷ +70oC liquid temperature  
1420 Pump with single front seal of 2100-type, with quenching, for -30oC ÷ +70oC liquid temperature            
1600 Pump with double front seal in BACK TO BACK V + V-type system with barrier liquid,
for -30oC ÷ +70oC liquid temperature
1610 Pump with double front seal in BACK TO BACK V + VB-type system with barrier liquid,
for -30oC ÷ +70oC liquid temperature
 
2020 Pump with cord seal,
for liquids of +70oC ÷ +110oC temperature
2040 Pump with cord seal and chamber
for +70oC ÷ +110oC liquid temperature
2100 Pump with single front seal of A1-type,
for +70oC ÷ +110oC liquid temperature
   
2110 Pump with single front seal of V-type,
for +70oC ÷ +110oC liquid temperature
 
2120 Pump with single front seal of V-type at suction side and VB-type at discharge side,
for +70oC ÷ +110oC liquid temperature
 
2130 Pump with single front seal of US-type, for +70oC ÷ +110oC liquid temperature  
2170 Pump with single front seal of 2100-type,
for +70oC ÷ +110oC liquid temperature
           
2230 Pump with single front seal of 58U-type,
for +70oC ÷ +110oC liquid temperature
     
2350 Pump with single front seal of A1-type, with quenching, for +70oC ÷ +110oC liquid temperature    
2360 Pump with single front seal of V-type, with quenching, for +70oC ÷ +110oC liquid temperature  
2370 Pump with single front seal of V-type at suction side and of VB-type at discharge side, with quenching, for +70oC ÷ +110oC temperature liquid  
2420 Pump with single front seal of 2100-type, with quenching, for +70oC ÷ +110oC temperature liquid            
2600 Pump with double front seal in BACK TO BACK V + V-type system with barrier liquid,
for +70oC ÷ +110oC liquid temperature
2610 Pump with double front seal in BACK TO BACK V + VB-type system with barrier liquid,
for +70oC ÷ +110oC liquid temperature
 

Supply completeness

1 - Pump with free shaft end.
2 - Pump with coupling.
3 - Pump with coupling and foundation plate.
5 - As in 3 plus electric motor.

Product cosmetics

  1. Standard
  2. Special

Budowa

SKA pumps consist of: bearing housings, shaft, suction and discharge housings in which shaft seals are installed. On the shaft impellers are mounted, their number depends upon the number of pump stages. Impeller positions are limited by limiting members. Suction member is located at suction housing, then come suction/discharge members and the last discharge member.

Features:

  • many years of reliable operation and easy access to replacement parts guaranteed,
  • execution of individual requirements and products adjusted to customer's needs,
  • permanent technical supervision as well as guarantee and post-guarantee service,
  • low procurement and operation costs,
  • relatively long life in difficult operational conditions.

SKA pumps sealing systems

      Cord seal system
Front single seal system      
      Cord with chamber seal system
System of front single seal with quenching      
      System of cord seal with circulation pipe
System of double front BACK TO BACK seal with barrier liquid      



Hydro-Vacuum S.A.
ul. Droga Jeziorna 8
86-303 Grudziądz
tel. 56 45 07 415
fax. 56 46 25 955
Copyright © Hydro-Vacuum S.A.

We’d like to inform that in order to optimize contents available in our website, to adapt them to individual needs of every user, as well as for statistic purposes we use information recorded by means of cookies files on users’ data terminal equipment. The user can control cookies files through settings of his internet browser. Further use of our internet service, without modification of settings of an internet browser, means that the user accepts policy of application of cookies files.